Abstract
The surface-matching registration method in the current neuronavigation completes the coarse registration mainly by manually selecting anatomical landmarks, which increases the registration time, makes the automatic registration impossible and sometimes results in mismatch. It may be more practical to use a fast, accurate, and automatic spatial registration method for the patient-to-image registration. A coarse-to-fine spatial registration method to automatically register the patient space to the image space without placing any markers on the head of the patient was proposed. Three-dimensional (3D) keypoints were extracted by 3D Harris corner detector from the point clouds in the patient and image spaces, and used as input to the 4-points congruent sets (4PCS) algorithm which automatically registered the keypoints in the patient space with the keypoints in the image space without any assumptions about initial alignment. Coarsely aligned point clouds in the patient and image space were then fine-registered with a variant of the iterative closest point (ICP) algorithm. Two experiments were designed based on one phantom and five patients to validate the efficiency and effectiveness of the proposed method. Keypoints were extracted within 7.0s with a minimum threshold 0.001. In the phantom experiment, the mean target registration error (TRE) of 15 targets on the surface of the elastic phantom in the five experiments was 1.17±0.04mm, and the average registration time was 17.4s. In the clinical experiments, the mean TRE of the targets on the first, second, third, fourth, and fifth patient's head surface were 1.70±0.32mm, 1.83±0.38mm, 1.64±0.3mm, 1.67±0.35mm, and 1.72±0.31mm, respectively, and the average registration time was 21.4s. Compared with the method only based on the 4PCS and ICP algorithm and the current clinical method, the proposed method has obvious speed advantage while ensuring the registration accuracy. The proposed method greatly improves the registration speed while guaranteeing the equivalent or higher registration accuracy, and avoids a tedious manual process for the coarse registration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.