Abstract

Ionized by solar radiation, the ionosphere causes a phase rotation or time delay to trans-ionospheric radio waves. Reconstruction of ionospheric electron density profiles with global navigation satellite system (GNSS) observations has become an indispensable technique for various purposes ranging from space physics studies to radio applications. This paper conducts a comprehensive review on the development of voxel-based computerized ionospheric tomography (CIT) in the last 30 years. A brief introduction is given in chronological order starting from the first report of CIT with simulation to the newly proposed voxel-based algorithms for ionospheric event analysis. The statement of the tomographic geometry and voxel models are outlined with the ill-posed and ill-conditioned nature of CIT addressed. With the additional information from other instrumental observations or initial models supplemented to make the coefficient matrix less ill-conditioned, equation constructions are categorized into constraints, virtual data assimilation and multi-source observation fusion. Then, the paper classifies and assesses the voxel-based CIT algorithms of the algebraic method, statistical approach and artificial neural networks for equation solving or electron density estimation. The advantages and limitations of the algorithms are also pointed out. Moreover, the paper illustrates the representative height profiles and two-dimensional images of ionospheric electron densities from CIT. Ionospheric disturbances studied with CIT are presented. It also demonstrates how the CIT benefits ionospheric correction and ionospheric monitoring. Finally, some suggestions are provided for further research about voxel-based CIT.

Highlights

  • The ionospheric electron density (IED) is one of the essential parameters to characterize the upper atmosphere of the earth and manifest the solar–terrestrial relation

  • As the ionospheric total electron content (TEC) is an integrated value of the IED along the ray path from a satellite to a receiver, this is analogous to computerized tomography (CT), which has been intensively studied for applications in various fields [1,2]

  • In computerized ionospheric tomography (CIT), the ionosphere is divided into threedimensional voxels, and some voxels are not traversed by any satellite-receiver rays

Read more

Summary

Introduction

The ionospheric electron density (IED) is one of the essential parameters to characterize the upper atmosphere of the earth and manifest the solar–terrestrial relation. While GNSS observation on a low earth orbit (LEO) satellite was used to inverse the ionospheric profiles at the tangent point [8], Hernández-Pajares et al (1998) [9] developed a method to reconstruct the threedimensional IED distribution on a global scale by using both receivers on ground and LEO satellites. This added horizontal satellite-receiver rays and increased the altitudinal resolution of IED.

Statement of Tomography Problem
Voxel-Based Models
Variable Voxel Geometry
Variable Voxel Size
Variable Voxel Homogeneity
Equation Constructions
Condition Constraint
Virtual Data Assimilation
Multi-Source Observation Fusion
Algorithms
Iterative Reconstruction
Singular Value Decomposition
Kalman Filtering
Neural Network
Bayesian Estimation
CIT Results and Applications
Ionospheric Height Profile and Image
Ionospheric Disturbance Study
Ionospheric Correction
Ionospheric Monitoring
Future Directions
Summary

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.