Abstract

We aimed to retrospectively evaluate the radiographic and clinical results and the success rate of short implants with a laser-microgrooved collar (≤7.5mm) placed in the posterior areas after up to 3 to 5years of function and the possible influence of several variables-such as gender, periodontitis, smoking habit, location, implant stability at placement, and prosthetic fixation design-on implant marginal bone loss (MBL). A chart review was used for this multicenter study, which involved 5 private dental clinics. All patients had been treated with short dental implants with a laser-microgrooved collar from January 2012 to December2015. A total of 174 patients (99 male and 75 female patients; mean age, 51.6±2.8years) with 254 implants were evaluated. Seven short implants failed. The cumulative success rate was 97.2%, without a statistically significant difference between implants placed in the posterior maxilla and mandible. The mean MBL was 0.18±0.7mm at the mesial aspect and 0.19±0.6mm at the distal aspect. No statistical relationships were found between MBL and gender, periodontitis, smoking habit, location, implant stability at placement, and prosthetic fixation design. At the end of the 3- to 5-year follow-up period, short implants with a laser-microgrooved collar (≤7.5mm) in the posterior areas yielded a relatively high cumulative success rate. The laser-microgrooved collar implant maintained stable marginal bone levels. No investigated variable was statistically associated with MBL.