Abstract
Cardiac electrophysiological computational models are often developed from previously published models. The new models may incorporate additional features to adapt the model to a different species or may upgrade a specific ionic formulation based on newly available experimental data. A relevant challenge in the development of a new model is the estimation of certain ionic current conductances that cannot be reliably identified from experiments. A common strategy to estimate those conductances is by means of constrained non-linear least-squares optimization. In this work, a novel methodology is proposed for estimation of ionic current conductances of cardiac electrophysiological models by using a response surface approximation-based constrained optimization with trust region management. Polynomial response surfaces of a number of electrophysiological markers were built using statistical sampling methods. These markers included action potential duration (APD), triangulation, diastolic and systolic intracellular calcium concentration, and time constants of APD rate adaptation. The proposed methodology was applied to update the Carro et al. human ventricular action potential model after incorporation of intracellular potassium ([K+]i) dynamics. While the Carro et al. model was well suited for investigation of arrhythmogenesis, it did not allow simulation of [K+]i changes. With the methodology proposed in this study, the updated Carro et al. human ventricular model could be used to simulate [K+]i changes in response to varying extracellular potassium ([K+]o) levels. Additionally, it rendered values of evaluated electrophysiological markers within physiologically plausible ranges. The optimal values of ionic current conductances in the updated model were found in a notably shorter time than with previously proposed methodologies. As a conclusion, the response surface optimization-based approach proposed in this study allows estimating ionic current conductances of cardiac electrophysiological computational models while guaranteeing replication of key electrophysiological features and with an important reduction in computational cost with respect to previously published approaches. The updated Carro et al. model developed in this study is thus suitable for the investigation of arrhythmic risk-related conditions, including those involving large changes in potassium concentration.
Highlights
The last decades have seen an extraordinary development of cardiac computational electrophysiological models
The framework has been applied to update a previously published human ventricular AP model, the CRLP model, by incorporating [K+]i dynamics. Such incorporation involves readjustment of ionic current conductances to avoid drifting in intracellular potassium
Our results demonstrate that with the proposed methodology it was possible to successfully update the CRLP model by incorporating [K+]i dynamics while keeping the model’s ability to reproduce risk-related markers for investigation of cardiac arrhythmias
Summary
The last decades have seen an extraordinary development of cardiac computational electrophysiological models The possibilities they offer to investigate the electrical behavior of the heart together with the large increase in computing capability have boosted such development. For each ionic current a mathematical formulation is employed to represent characteristics like gating or permeability of the corresponding ion channels. Those formulations rely on a number of model parameters which values are commonly estimated based on experimental data obtained from specific protocols for each ionic current. In this context parameter estimation presents various shortcomings intrinsic to the voltage-clamp experimental protocols [1]: i) insufficient separation of ionic current activation and inactivation processes; ii) use of non-selective pharmacological ion channel blockers; and iii) measurement of non-physiological solutions
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.