Abstract

This paper describes a general practice based diabetic retinopathy screening service employing a technician trained in direct and indirect ophthalmoscopy and taking photographs with a Canon CR3 45 NM non-mydriatic polaroid camera analysed by a consultant ophthalmologist to provide a comparison with the screener's opinion. Prospective data is presented from the first 1050 patients screened for diabetic retinopathy in the Exeter Health Authority area. Analysis of data collected showed a prevalence of diabetic retinopathy in the screened population of 27%, 14% previously undetected with a 0.5% prevalence of sight-threatening retinopathy. There was almost complete agreement between ophthalmoscopy findings and the consultant analysis of photographs. Screening costs were calculated at 10.38 pounds per patient screened. A specially trained non-medically qualified technician can provide a good quality cost-effective screening service for diabetic retinopathy within a primary care setting.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.