Abstract

The effect of plasma nitriding on the fatigue life of AISI 4140 steel having a certain fatigue loading has been investigated. Untreated and nitrided specimens were subjected to fatigue loading up to a certain level, and then nitrided for 0.5 h and subjected to fatigue testing again. It was observed that the process applied to untreated specimens improves the fatigue life of the specimens that were plasma nitrided for 0.5 h due to the subsurface crack nucleation. However, for already nitrided specimens, a significant improvement in the fatigue life has not been observed by applying the proposed process because the compound layer on the surface prevents the diffusion during the second nitriding.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.