Abstract

An analysis of aerobic m-xylene biodegradation kinetics was performed on the results of laboratory batch microcosms. A modified version of the computer model BIO3D was used to determine the Monod kinetic parameters, k max (maximum utilization rate) and K S (half-utilization constant), as well as the Haldane inhibition concentration, K I, for pristine Borden aquifer material. The proposed method allows for substrate degradation under microbial growth conditions. The problem of non-uniqueness of the calculated parameters was overcome by using several different initial substrate concentrations. With a relative-least-squares technique, unique kinetic degradation parameters were obtained. Calculation of the microbial yield, Y, based on microbial counts from the beginning and the end of the experiments was crucial for reducing the number of unknowns in the system and therefore for the accurate determination of the kinetic degradation parameters. The kinetic parameters obtained in the present study were found to agree well with values reported in the literature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.