Abstract

A recoil separator in combination with a windowless gas target has been designed for the measurement of the radiative capture reaction p(7Be, γ)8B. The separator consists of momentum and velocity filters and a ΔE−E detector telescope. The setup was tested quantitatively using the p(12C, γ)13N reaction at the effective energy Ecm = 841 keV. Projectile fluxes were measured directly with Faraday cups and indirectly with elastic backscattering into Si detectors, while the 13N recoil flux was measured directly with the ΔE−E telescope. A suppression of the 12C beam particles by a factor 2 × 10−10 was observed when the system was tuned for the recoil 13N's. Special emphasis was given to the charge state probabilities of the 13N recoils. Possible improvements of the system for the measurement of other capture reactions are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.