Abstract
While the low dispersion IUE NEWSIPS data products represent a significant improvement over original IUE SIPS data, they still contain serious systematic effects which compromise their utility for certain applications. We show that NEWSIPS low resolution data are internally consistent to only 10-15% at best, with the majority of the problem due to time dependent systematic effects. In addition, the NEWSIPS flux calibration is shown to be inconsistent by nearly 10%. We examine the origin of these problems and proceed to formulate and apply algorithms to correct them to ~ 3% level -- a factor of 5 improvement in accuracy. Because of the temporal systematics, transforming the corrected data to the IUE flux calibration becomes ambiguous. Therefore, we elect to transform the corrected data onto the HST FOS system. This system is far more self-consistent, and transforming the IUE data to it places data from both telescopes on a single system. Finally, we argue that much of the remaining 3% systematic effects in the corrected data is traceable to problems with the NEWSIPS intensity transformation function (ITF). The accuracy could probably be doubled by rederiving the ITF.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.