Abstract

Pneumocystis jiroveci is an important cause of pneumonia in immunocompromised individuals. This organism cannot be cultured, and therefore, diagnosis relies on microscopic identification of the organism using stains or antibodies. Although simple, these tests are insensitive and require expertise for accurate interpretation. We developed a real-time polymerase chain reaction (PCR) assay that provides sensitive and objective detection of Pneumocystis from bronchoalveolar lavage fluid. Primers and fluorescence resonance energy transfer probes were developed that target the cdc2 gene of P. jiroveci. Assay sensitivity is 6 copies of target per microliter of sample. No cross-reactivity occurs with other pathogens, and the PCR assay has a 21% increase in clinical sensitivity as compared with Calcofluor white staining. The real-time PCR assay provides a sensitive, rapid, and objective method for the detection of Pneumocystis from bronchoalveolar lavage fluid.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.