Abstract

We developed and assessed a real-time 3-dimensional (3D) digital Doppler method for measurement of flow volumes through the mitral valve in children. A total of 13 children (aged 10.46 +/- 2.5 years; 8 boys/5 girls) were enrolled. An ultrasound system (Sonos 7500, Philips, Andover, Mass) was used to acquire raw 3D velocity data for flow measurement based on Gaussian control surface theorem [flow (mL/s) = mean velocity x flow area]. Stroke volume (SV) measured by real-time 3D digital Doppler with the control surface at the mitral valve annulus or orifice was compared with the SV by phase velocity cine magnetic resonance imaging (MRI) at the ascending aorta and by left ventricular volumetric MRI measurement. The best correlation and agreement were seen at the mitral valve orifice by real-time 3D digital Doppler compared with SV by phase velocity cine MRI at the ascending aorta (r = 0.92, mean difference = -5.2 +/- 12.0 mL) and SV by left ventricular volumetric MRI measurement (r = 0.94, mean difference = -0.2 +/- 10.3 mL).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.