Abstract

An MRPC prototype for the future CBM-TOF inner area has been developed. The counter assembled with low resistive glass consists of 10×0.22 mm gas gaps and 2×8 readout pads. The size of each pad is 20 mm×20 mm with an interval of 2 mm between pads. The signals of the counter are collected by 4 eight-pin connectors. Preliminary tests performed with cosmic-rays showed an efficiency over 98% and a time resolution around 60 ps. The measured crosstalk, dark current and dark rate were at a very low levels. Results under uniform irradiation performed at JINR with high energy deuteron showed a time resolution of 40–50 ps and over 98% efficiency at a low flux rate, meanwhile at a flux up to 70 kHz/cm2, 93% efficiency and 77 ps time resolution still remained. These excellent performances call fully meet the demand of CBM-TOF inner wall.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.