Abstract

An on-line method of predicting reactor water level and pressure under small loss-of-coolant-accident (LOCA) conditions has been proposed. The method features initialization of a simplified reactor model in transient conditions. This is done by using plant data in time series and estimating unknown parameters, such as break area, by a nonlinear optimization method. Off-line simulations were performed for small LOCAs (break area: ∼100 cm2) using the results of a reference LOCA analysis code for plant data. These showed that the difference from the reference calculation during a 10-min period was within 10%, normalized by the value at the initialization time, and the estimation error for break area was below 11%. The overall CPU time required for the prediction was below 10 s in a general purpose computer of 10 million instructions per second.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.