Abstract

This article describes the development of a new experimental model using rats for the evaluation of small-caliber vascular grafts. By modifying heterotopic heart transplantation, two 1.5- to 2.0-cm long vascular prostheses were interposed between a syngeneic donor heart and the recipient abdominal vessels in the form of vascular bridges. Once blood flow through the vascular grafts was reestablished, the donor heart resumed normal beating. The status of the vascular grafts could be easily monitored by palpation. Occlusion of the grafts stopped donor heart beating without affecting survival of the animals. Once the surgical method was mastered, the postoperative mortality was approximately 10%, and the total procedure took less than 2 hours. Although microvascular surgical technique and equipment are required, this model has several advantages, including easy detection of thrombotic occlusion of the grafts, the use of small animals of defined genetic background, the absence of effect of graft occlusion on the recipient's life, and possible repeated operation on the same animal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.