Abstract

We report a rare complication of TEP herniorrhaphy. A 47-year-old man underwent TEP inguinal hernia repair. Bladder rupture was noted after balloon dissection. The defect was sutured, and the hernia was repaired under laparoscopy. Cystoscopy showed the site of injury at anterior bladder neck. This is the first report of bladder rupture associated with balloon dissector in a patient with no prior abdominal surgery.