Abstract

We report a rare case of idiopathic spinal cord herniation (ISCH) with a history of cerebrospinal fluid (CSF) leakage. ISCH is a protrusion of the spinal cord through a dural defect. Thin constructive interference in steady-state (CISS) images clearly demonstrated the herniated cord in the present case. The myelopathy worsened and the patient underwent surgery for reduction of herniated spinal cord; the dural defect was filled by placing collagen matrix graft (DuraGen®) between the inner and outer dural layers. The patient's symptoms have improved without relapse for 8 months since surgery. This method may be a good surgical option for cases of spinal cord herniation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.