Abstract

A high-voltage nanosecond impulse generator was developed and tested in order to create electromagnetic impulses (EMIs) in a given area. Tests revealed the characteristics of the generator’s output impulse: the rise (at a level 0.1–0.9) is about 3.2 ns, the length is 27 ns at half-deflation, and the magnitude is 2 MV. The generator is used to test large-size equipment for tolerance to industrial EMIs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.