Abstract
Prospectively to compare success rate and complications in percutaneous transluminal coronary angioplasty using two doses of heparin. Four hundred patients undergoing coronary angioplasty were randomly assigned to receive 15,000 IU (group A) or 100 IU.kg-1 (group B) of heparin. The angioplasty success rate was 95% of both groups. Stents were placed in 28.5% and 26.5% of patients in groups A and B, respectively (P = 0.73). The primary endopoint (freedom from death, myocardial infarction, unplanned revascularization or bailout stenting) occurred in 91% vs 95% of patients in groups A and B, respectively (odds ratio: 1.88, 95% CI: 0.80-4.50, P = 0.12). Haemoglobin loss was 0.36 +/- 1 and 0.27 +/- 0.9 g.dl-1 in groups A and B, respectively (P = 0.37). The time to sheath removal (735 +/- 265 vs 558 +/- 246 min) and the time to transfer to a stepdown unit (12.7 +/- 4.5 vs 9.8 +/- 4.2 h) were longer in groups A (P = 0.0001 for both comparisons). A weight-adjusted low dose of intravenous heparin is at least as safe as a fixed high dose for coronary angioplasty. It allows earlier sheath removal and discharge to a stepdown unit.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.