Abstract
The objective of the study was to test the hypothesis that Dilapan-S is not inferior to the Foley balloon for preinduction cervical ripening at term. Pregnant women ≥37 weeks scheduled for induction with unfavorable cervix (≤3 cm dilated and ≤60% effaced) were randomly assigned to 12 hours of either Foley balloon inflated with 60 mL saline or Dilapan-S for cervical ripening. If the cervix remained unfavorable, then 1 more round of the assigned dilator was used. Management following ripening was left up to the clinical providers. The primary outcome was vaginal delivery. A satisfaction survey was also obtained after the preinduction period. Sample size was based on a noninferiority margin of 10%, 90% power, and an estimated frequency of vaginal delivery of 71% in Foley balloon and 76% in Dilapan-S. From November 2016 through February 2018, 419 women were randomized (209 to Foley balloon; 210 to Dilapan-S). In the intent-to-treat analysis, vaginal delivery was more common in Dilapan-S vs Foley balloon (81.3% vs 76.1%), with an absolute difference with respect to the Foley balloon of 5.2% (95% confidence interval, -2.7% to 13.0%) indicating noninferiority for the prespecified margin. The difference was not large enough to show superiority. Noninferiority was confirmed in the per-protocol population (n= 204 in the Foley balloon, n= 188 in Dilapan-S), supporting the robustness of the results. Secondary outcomes were not different between groups, except for a longer time the device remained in place in Dilapan-S compared with the Foley balloon. Maternal and neonatal adverse events were not significantly different between groups. A priori interaction analyses showed no difference in the effect on vaginal delivery by cervical dilation at randomization, parity, or body mass index >30 kg/m2. Patients with Dilapan-S were more satisfied than patients with the Foley balloon as far as sleep (P= .01), relaxing time (P= .001), and performance of desired daily activities (P= .001). Dilapan-S is not inferior to the Foley balloon for preinduction cervical ripening at term. Advantages of Dilapan-S over Foley include Food and Drug Administration approval, safe profile, no protrusion from the introitus, no need to keep under tension, and better patient satisfaction.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.