Abstract

Anterior cervical discectomy and fusion (ACDF) may be performed using an interbody cage or graft with an anterior plate or with a stand-alone (SA) interbody device without the anterior plate. The pros and cons of each vary. This study examined the radiographic outcome of the two techniques with a focus on implant subsidence. A retrospective review of cases of singe level ACDF by a single surgeon was undertaken. Medical and radiographic records were reviewed to determine subsidence, pre- and post-operative segmental and total lordosis in cohorts of both stand-alone and graft-and-plate constructs. The post-operative radiographs of 35 patients with a SA cage were compared with 41 patients with an allograft block and anterior plate (graft and plate; GP). There was no significant difference in overall subsidence between the two groups although there was a trend toward less clinically significant subsidence (2 mm) in the SA group. For single level ACDF, a SA device appears to be comparable in terms of undesired subsidence. Further studies with different implants and materials may offer further insight.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.