Abstract

In an operating plant quick reporting of the status of long-lived alpha activity concentrations in the work atmosphere is required. This will help in taking any corrective control measures if required. Radon and thoron progeny concentrations prevalent in the general atmosphere predominantly interfere in measurement of long-lived alpha activity in air. The alpha counts due to radon and thoron progeny vary widely in many atmospheric conditions. Therefore, conventionally, 5 days delay is allowed for all interfering activity to decay completely and true alpha air activity is then estimated. An approach for quick assessment of long-lived alpha activity by eliminating interference due to radon and thoron progeny in air, is made here. Based on the study of the pattern of alpha count rate due to radon and thoron progeny in air, a method for estimation of long-lived alpha activity within 8 hours delay time is suggested in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.