Abstract

AbstractAccelerated electromigration tests were performed in a High Voltage SEM (HVSEM). These experiments were conducted on 10 identical, passivated Al interconnect test structures at a temperature of 237°C and a current density of 30mA/µm2. Simultaneous testing and observation of the entire structure allowed the void nucleation times to be measured. Two normal distributions fit the nucleation times. The second of these distributions coincides roughly with the distribution of failure times of the test structures. Fracture of the passivation is hypothesized as the mechanism that causes the concurrent late nucleation and failure processes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.