Abstract

In this paper, a new optimal pulsewidth modulation (PWM) scheme for a three-level quasi-switched boost T-type inverter (TL qSBT2I) under normal and failure modes is proposed. The proposed method reveals its semiconductor fault tolerance capability in open-circuit fault condition situations as described in this paper. The PWM control algorithm for the fault-tolerant qSBT2I is implemented by selecting appropriate values for the modulation index, shoot-through (ST) duty cycle, and duty cycles of two additional switches. The steady-state analysis and operating principles of the fault-tolerant qSBT2I are presented. A laboratory prototype was built to verify the operating principles of the qSBT2I with the proposed modulation scheme before and after fault conditions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call