Abstract

A power conditioning system (PCS) using multiple module-integrated converters and a single sourced 27-level asymmetric cascaded H-bridge multilevel inverter (MLI) without regeneration for photovoltaic (PV) applications is proposed. A newly suggested hybrid-switching closed-loop strategy is proposed to enable the use of a 27-level inverter in PV systems. The suggested hybrid-switching strategy implements fundamental line-frequency switching in the main H-bridge to ensure a high efficiency and low leakage current operation. Furthermore, high-frequency switching is used in the auxiliary H-bridge cells to achieve a higher bandwidth control loop. A cost-effective unidirectional single-ended 1-kW dc–dc module based on a boost coupled inductor and charge-pump circuits is proposed to achieve a single PV source per module for a multistring configuration. To couple the unidirectional converters with the central inverter, a jumping element in the hybrid switching strategy is introduced to enable an optimal nonregenerative operation. The proposed PCS with the control scheme is analyzed and verified using hardware results in a grid connected mode of operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.