Abstract

Pacemakers set in a bipolar pacing mode often result in no discernible spikes on surface 12‑lead ECG registrations. In this situation, left axis deviation combined with wide QRS can help to identify the paced ECG morphology. We present a case of a non-pacemaker dependent patient whose normal atrioventricular conduction also appeared as atypical left axis deviation with wide QRS on the ECG. These two depolarization-repolarization morphologies, and the switch between the two raised differential diagnostic questions. The case also illustrates a paced ECG demonstrating the concept of Littmann: a close relationship between leads V2 and aVL.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.