Abstract

To develop and validate a prostate cancer (PCa) risk calculator (RC) incorporating multiparametric magnetic resonance imaging (mpMRI) and to compare its performance with that of the Prostate Biopsy Collaborative Group (PBCG) RC. Men without a PCa diagnosis receiving mpMRI before biopsy in the Prospective Loyola University mpMRI (PLUM) Prostate Biopsy Cohort (2015-2020) were included. Data from a separate institution were used for external validation. The primary outcome was diagnosis of no cancer, grade group (GG)1 PCa, and clinically significant (cs)PCa (≥GG2). Binary logistic regression was used to explore standard clinical and mpMRI variables (prostate volume, Prostate Imaging-Reporting Data System [PI-RADS] version 2.0 lesions) with the final PLUM RC, based on a multinomial logistic regression model. Receiver-operating characteristic curve, calibration curves, and decision-curve analysis were evaluated in the training and validation cohorts. A total of 1010 patients were included for development (N = 674 training [47.8% PCa, 30.9% csPCa], N = 336 internal validation) and 371 for external validation. The PLUM RC outperformed the PBCG RC in the training (area under the curve [AUC] 85.9% vs 66.0%; P < 0.001), internal validation (AUC 88.2% vs 67.8%; P < 0.001) and external validation (AUC 83.9% vs 69.4%; P < 0.001) cohorts for csPCa detection. The PBCG RC was prone to overprediction while the PLUM RC was well calibrated. At a threshold probability of 15%, the PLUM RC vs the PBCG RC could avoid 13.8 vs 2.7 biopsies per 100 patients without missing any csPCa. At a cost level of missing 7.5% of csPCa, the PLUM RC could have avoided 41.0% (566/1381) of biopsies compared to 19.1% (264/1381) for the PBCG RC. The PLUM RC compared favourably with the Stanford Prostate Cancer Calculator (SPCC; AUC 84.1% vs 81.1%; P = 0.002) and the MRI-European Randomized Study of Screening for Prostate Cancer (ERSPC) RC (AUC 84.5% vs 82.6%; P = 0.05). The mpMRI-based PLUM RC significantly outperformed the PBCG RC and compared favourably with other mpMRI-based RCs. A large proportion of biopsies could be avoided using the PLUM RC in shared decision making while maintaining optimal detection of csPCa.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.