Abstract

To the Editor, We share our experience with a new catheter securement device called the (Interrad Medical, Plymouth, MN, USA). It utilizes small folding subcutaneous nitinol tines that anchor an intravenous catheter at the insertion site (Figure, panels A and B). The anchor is designed to be atraumatic, and it is magnetic resonance imaging compatible. An instructional video provided by the manufacturer is available at http://interradmedical. com/video-short-demo. We conducted a multicentre observational postmarketing study to evaluate the effectiveness of successful catheter securement with this device. The study was approved by the Research Ethics Board of each participating institution (listed below) and was registered at www.clinicaltrials.gov (NCT00903539). Physicians were trained by the manufacturer on the use of the SecurAcath, and consenting patients 18 yr or older requiring a 7Fr central venous catheter (CVC) in the internal jugular vein were enrolled in the study. Seventyfour subjects were included from June 23, 2010 to January 4, 2011. The primary outcome, successful securement, was achieved in 72 (97%) of the cases. Two patients experienced catheter dislodgement, attributed to improper coupling of the two device components. These were identified within 24 hr of catheter placement. No other device-related malfunction occurred. There were no device-related adverse events, such as catheter migration within the device, difficulties with removal, cellulitis at the site, or erosion at the anchor securement site. The immediate procedural success rate was 100%. The mean (standard deviation) time to secure the catheter was 62.5 (97.3) sec, and 91% of the devices were deployed within 2.5 min. Mean catheter indwelling time was 3.1 (5.1) days. Discomfort analogue score (scale 1-10) during device use and at removal was 0.9 (1.6) and 1.6 (2.1), respectively. Fourteen of the 15 patients with previous CVC or a peripherally inserted central catheter experience considered SecurAcath to be as or more comfortable than a sutured catheter. Six of the eight healthcare professionals questioned thought that maintenance of the device site was somewhat or much easier than with a sutured catheter, and all stated they would recommend this device to other professional colleagues. Anesthesiologists commonly perform CVC placement, and most often this is sutured for stabilization. The American Society of Anesthesiologists (ASA) believes that the literature is currently insufficient to evaluate the usefulness of sutureless stabilization; therefore, the ASA Task Force suggested that the decision should be determined on an institutional basis. By contrast, multiple medical societies advocate sutureless securement devices in order to reduce the risk of infection. It is believed that skin disruption near the catheter entry site is associated with increased risk of infection. Furthermore, avoidance of suturing is consistent with prevention of needlestick injury (NSI). The use of staples addresses the issue of NSI but still results in skin disruption. Adhesive-based securement systems appear to have better efficacy and safety profiles compared with sutures. A subset of patients, however, may be unsuitable for skin adherence because of hair growth, skin lesions, allergy to the adhesive, or diaphoresis. In addition, both adhesive-based and staple-based devices pose similar hygiene challenges during dressing changes as D. Cordovani, MD (&) ! R. M. Cooper, MD Department of Anesthesia and Pain Management, Toronto General Hospital, Toronto, ON, Canada e-mail: dancordovani@hotmail.com

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.