Abstract

Patients with an isolated spiral or long oblique fracture of the proximal phalanx were randomized into two groups. One was treated by closed reduction and Kirschner wire fixation and the second treated by open reduction and lag screw fixation. An independent observer assessed function, pain, movement, grip strength and intrinsic muscle function. X-rays were assessed for malunion. Thirty-two patients were entered the study and 15 in the Kirschner wire and 13 in the lag screw group were reviewed at a mean follow-up of 40 months. There was no significant difference in the functional recovery rates or in the pain scores for the two groups. X-rays showed similar rates of malunion and there were no statistically significant differences in range of movement or grip strength.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.