Abstract

To the Editor, Quality and safety are major initiatives of the anesthesia community. Periodic evaluation of procedural skills could potentially decrease the risk of common and potentially dangerous errors while promoting self-awareness. Although infectious complications following neuraxial anesthesia are rare, they remain a significant cause of morbidity/mortality and subsequent litigation. We queried whether introducing the new Wiley Spinal neuraxial kit (Epimed, NY, USA) for continuous spinal anesthesia (CSA) would affect sterile technique when compared with B. Braun’s custom kit (B. Braun, PA, USA) for combined spinal-epidural anesthesia (CSE) used in our hospital. After anesthesiologists and fellows (subjects) received training in the new CSA kit, we compared the number of breaches in sterile technique that occurred when the subjects used the two kits in a simulation session. Following approval by the University of British Columbia Research Ethics Board (March 2012) and informed consent, each subject (n = 12) was trained using a lumbar model, GENESIS Simulator (Epimed International, Farmers Branch, TX, USA), to perform CSA with the new kit. Interventions and observations were completed during March-July 2012. Within five weeks following their training, the subjects randomly used the CSE and CSA kits in a videotaped simulation session. To ensure that the videotape assessors were blinded to the subjects’ identity, all subjects wore masks, gowns, and gloves to conceal their hands and forearms, and no panoramic views or sounds were captured. Comments were elicited about the kits and lumbar model, and satisfaction was scored on a five-point Likert scale (5 = very satisfied). Two blinded assessors compared the performances randomly using a pre-established checklist to evaluate possible contamination of the operating field. A point was deducted if a breach occurred. Sterile skin preparation and opening the kit were not evaluated in order to focus on draping and handling of needles/catheter for breaches in aseptic technique. The videotapes were scored using the checklist. The areas assessed for breaches in aseptic technique were: placement of the drape on the model, placement of items on the tray and table, awareness of hand location, and handling the needles and catheter. A priori, maintenance of sterility during insertion was the surrogate for assessing risk of infection (safety). The number of breaches was similar between the two kits (Wilcoxon signed-rank test: W = 42; P = 0.14). The median (range) number of breaches in the CSA vs CSE group was 3 (1-4) vs 2 (0-5), respectively. The median (range) difference in the number of breaches (CSA-CSE) was 1 (-3 to 3). The total number of breaches was calculated for each subject for each technique and compared with the number S. Benavides, MD (&) Department of Anesthesia, BC Women’s Hospital, University of British Columbia, Vancouver, BC, Canada e-mail: sandritabds@gmail.com

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.