Abstract

Dabigatran is an oral anticoagulant that is increasingly used for atrial fibrillation (AF). Presently, many authorities state that routine laboratory coagulation monitoring is not required. However, data have recently been published demonstrating that higher trough plasma dabigatran concentrations are associated with lower thromboembolic and higher haemorrhagic event rates. Using these data, we simulate a range of AF patients with varying risks for these events and derive a target range of trough plasma dabigatran concentrations (30-130 μg l(-1) ). Finally, we propose that a conventional screening coagulation assay, the thrombin time (TT), can be used to discern whether or not patients are within this range of dabigatran concentrations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.