Abstract
A thermodynamic analysis of a simple inverse cycle is proposed as a means to evaluate mixtures of CO2 and four organic substances (propane, iso-butane, dimethyl-ether and propylene) as working fluids. The cycle features an internal heat exchanger and is designed to cool down a finite heat capacity flow on the cold side. The analysis covers trans-critical as well as sub-critical cycles. For each organic substance, the composition is optimized. Flammability is accounted for. Dimethyl-ether (DME) turns out to be the best option, as a relatively low mass fraction of this compound is sufficient for reaching the thermodynamic optimum. In this way, a simple, sub-critical refrigeration system may be obtained featuring a non-flammable working fluid and a significant COP increase with respect to pure CO2.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.