Abstract

In this paper aims at monitoring parameter of induction motor like current, voltage, torque and efficiency in real time by employing embedded system with wireless sensor networks. An embedded system is employed for acquiring electrical signals from the motor in a noninvasive manner, and then performing local processing for torque and efficiency estimation. The values calculated by the embedded system are transmitted to a monitoring unit through an IEEE 802.15.4-based Wireless Sensor Network (WSN). At the base unit, various motors can be monitored in real time. The Air Gap Torque (AGT) method is used to find out the torque and efficiency in induction motor. It is used to measure efficiency in a much less invasive manner. The AGT method can be employed without interrupting the motor operation and it is not based on the motor nameplate. This method generally is more accurate than the other methods. The proposed model has a supervisor (PC) which Communicates with the remote terminal unit, processing the variable parameters and controlling the systems. The Receiver Terminal Unit (RTU) is a local controller in distributed processes environmental which acquires the data from sensors, process the collected data puts the required data together, forming the frame for transmitting to the Supervisory Controls (S.C). RTU also receives and processes Control commands from S.C. and executes them accordingly. The communication utilizes a full duplex communication for data transmission between S.C. and RTU. The communication through wireless by using Zigbee.

Highlights

  • Torque EstimationIn an induction motor, the air gap is the region between stator and rotor, where occurs the electromechanical conversion process

  • The Air Gap Torque (AGT) method can be employed without interrupting the motor operation and it is not based on the motor nameplate

  • This paper presents an embedded system for determining torque and efficiency in industrial electric motors by employing Wireless Sensor Network (WSN)

Read more

Summary

Intoduction

In industrial environment most of the electric motor are induction[1] based because their cost effectiveness and mechanical robustness[2].Torque is the one of the main parameter of the induction motor[3] identifying this parameter will helpful to find out the equipment failure in induction motor. Soundarapandian and the current method[13] These methods present as the main limiting factors the low accuracy, estimative based on nominal motor data and the need of typical efficiency-versus-load curves. The AGT method can be employed without interrupting the motor operation and it is not based on the motor nameplate. This method generally is more accurate than the other methods described earlier. We have adopted the IEEE 802.15.4 standard for wireless communication This standard allows the formation of a large network of sensors, in various industrial segments, where the standard is expected to have a significant impact. In comparison with other standards such as IEEE 802.11 and IEEE 802.15.1 (Bluetooth), the IEEE802.15. standardhave advantages related to energy consumption, scalability, reduced time for node ­inclusion, and low cost

Motivation
System Architecture
Activity Diagram
Background
Efficiency Estimation
Industrial WSN
Matlab Simulation
10. Conclusion
Findings
11. References

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.