Abstract
Inelastic analysis of a prototypic liquid metal fast breeder reactor (LMFBR) piping system is generally performed without explicit consideration of time-dependent seismic loading. This paper presents an approximate procedure to simulate dynamic seismic loading as an equivalent static load for inelastic analysis. This procedure utilizes the results of the available linear seismic response spectrum analysis to calculate external (statically equivalent) loads. These statically equivalent loads are selected such that they produce internal forces and moments comparable to those predicted by the linear response spectrum analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.