Abstract
Problems of optimizing of the power consumption of a CMOS charge-sensitive amplifier for reading out the signals of multichannel silicon and gas detectors with capacitances up to 100 pF are discussed. In multichannel systems, the power consumption of electronics is limited. In this case it is required to achieve the optimal set of parameters of a charge-sensitive amplifier, and, in the first place, not to exceed the permissible noise and power consumption levels. The procedure for optimizing the parameters of the input transistor for reaching the minimal power consumption at the specified noise level of the charge-sensitive amplifier is described.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.