Abstract

We have investigated the application of an hydraulic orifice equation for the computation of diastolic mitral valve area in conditions of regurgitation. The new equation is given by Af = 21 Vf/T2, where Af is the total forward flow mitral valve area in cm2, Vf is the diastolic filling volume in ml, T is the diastolic filling period and 21 is a discharge coefficient derived from clinical haemodynamic data. Areas computed by the new formula correlate with valve areas as computed by the Gorlin formula at a level given by r = 0.93, n = 27. The results suggest that the new formula may be utilised in the context of mitral insufficiency and further, considerating the nature of the haemodynamic variables involved, an echographic quantification of this condition by M-mode or bidimensional echocardiography may be possible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.