Abstract

Venturi is one of the most commonly used flowmeters for measuring gas-liquid flow at the natural gas wellhead. A better understanding of the flow mechanism and the causes for pressure drop is necessary for the establishment of the measurement model. In this study, a one-dimensional pressure drop model between the two pressure taps of Venturi has been proposed for vertical annular-mist flow. The relations between the liquid film, entrainment rate, void fraction, and velocity slip have been revealed when the annular flow went through Venturi. We consider the gas acceleration in the throat of Venturi. The proportions of various pressure drops are given. The experimental results show that the relative errors of the pressure drop have a confidence probability of 98.5% within 10%. The predicted results are also in good agreement with the on-site data. It proves that the new pressure drop model has good performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.