The SCAPE (SuperConducting Arbitrarily Polarizing Emitter) undulator is under development at the Advanced Photon Source (APS). This new undulator requires a cryostat that will be designed based on expected heat loads. For instance, the expected heating of the beam chamber by electron beam is estimated to be at a level of 182 W - much higher than in planar SCUs. This and other challenges require careful thermal analysis of the LHe-based SCAPE cryostat. A detailed thermal model of the LHe-based SCAPE cryostat has been created in ANSYS. This paper presents calculated cooling capacity and temperatures of the SCAPE cryostat for the static and dynamic heat loads.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.