Abstract

On the basis of the relevant identification theory of pseudo-random code signal, the signals of CSAMT are divided into three parts according to the frequency of the signal. The signals which are susceptible to 50Hz interference signal and its harmonic components should be set by pseudo-random code way. Others are set by single square waveform way. The Control and signal generation software of the transmitter system is built on the advanced virtual instrument platform, LabVIEW. The hardware of the transmitter system is mainly composed of host computer, data acquisition card, high-speed optocoupler, IGBT driver module and four IGBT switches. The data acquisition card generate PWM signals, the high-speed optocoupler isolates low-voltage part and high-voltage part. IGBT drive module and four IGBT switches constitute high-voltage part. Entire transmitter system is suitable for different environments and research tasks, the transmit frequency are adjustable, and the pseudo-random code signal has strong capability to suppress the interference signals. The control software on host computer is simple and clear. There is good prospect for the use.