Abstract

Objective To explore the feasibility of the volume modulated arc therapy (VMAT) auto-planning based on template library (TL). Methods VMAT plans of 68 patients diagnosed with postoperative rectal cancer in Eclipse system were retrospectively selected. The prescription dose was 50 Gy/25F. In 19 patients, the feature values of target and organs at risk were extracted as the vectors. The final optimized restricted conditions were saved as the TL. Then, the plans of 15 rectal cancer patients (10 cases from TL and 5 outside TL) were automatically optimized. According to the multi-dimensional vector similarity principle, the similarity parameter αwas defined. The designed program automatically selected the optimal-object template in an in-house software developed with Matlab. The dosimetric parameters of the auto-optimized plans with the optimal-object template (ATP) and the clinical plan (CP) were compared by the paired t-test. The changes in the dosimetric parameters and similarity parameter α were statistically compared by Pearson′s correlation analysis. The linear fitting of the dosimetric parameters with α was used by least squares method to explore the tendency of the ATP dosimetric parameters relative to CP. Results The dosimetric parameters of ATP for 13 cases were slightly worse than those of CP. The conformal index (P=0.004), heterogeneous index (P=0.015), V40(P=0.003) and mean dose (P=0.022) of the intestine significantly differed. The α values of these 13 cases were 2.67, 2.60, 2.60, 2.49, 2.67, 2.74, 2.72, 2.48, 2.53, 2.86, 2.68, 2.56 and 2.63. The α value was significantly correlated with the V40 or mean dose of the bladder (r=0.649 and 0.603, P=0.016 and 0.029). Along with the increase of α value, V40 and mean dose of the intestine for ATP were gradually deteriorated than those of CP. The remaining dosimetric para-meters of ATP were close to or superior to those of CP. Conclusions The results of ATP are slightly worse than those of CP, whereas can satisfy the clinical requirements. The TL, the quality of TL and ATP remain to be further optimized. Key words: Radiotherapy; Template library; Auto-optimize; Volume modulated arc therapy plan

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.