Abstract
BackgroundThe diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore, to avoid possible refractive surgery that could produce ectasias. This study aims to describe the topographic, pachymetric and aberrometry characteristics in patients with keratoconus, subclinical keratoconus and normal corneas. Additionally to propose a diagnostic model of subclinical keratoconus based in binary logistic regression models.MethodsThe design was a cross-sectional study. It included 205 eyes from 205 patients distributed in 82 normal corneas, 40 early-stage keratoconus and 83 established keratoconus. The rotary Scheimpflug camera (Pentacam® type) analyzed the topographic, pachymetric and aberrometry variables. It performed a descriptive and bivariate analysis of the recorded data. A diagnostic and predictive model of early-stage keratoconus was calculated with the statistically significant variables.ResultsStatistically significant differences were observed when comparing normal corneas with early-stage keratoconus/ in variables of the vertical asymmetry to 90° and the central corneal thickness. The binary logistic regression model included the minimal corneal thickness, the anterior coma to 90° and posterior coma to 90°. The model properly diagnosed 92% of cases with a sensitivity of 97.59%, specificity 98.78%, accuracy 98.18% and precision 98.78%.ConclusionsThe differential diagnosis between normal cases and subclinical keratoconus depends on the mínimum corneal thickness, the anterior coma to 90° and the posterior coma to 90°.
Highlights
The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus
A cross-sectional study was carried out to analyses the topographic, pachymetric and aberrometry variables obtained by rotary Scheimpflug camera (Pentacam® type) from patients diagnosed with keratoconus, subclinical keratoconus and normal corneas in the Ophthalmology Service at the Torrecárdenas University Hospital (Almería, Spain) between February 2018 and February 2019
This study calculates a diagnostic model based on the aberrometry data of the anterior and posterior corneal surface provided by the Pentacam
Summary
The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Keratoconus is an asymmetrical bilateral eye disease [1] in which corneal thinning and protrusion occurs in the form of a generally lower temporal cone. This corneal deformation produces a significant decrease in visual quality. It has been seen that in Europe, the frequency would be between 5 and 23 per 100,000 people/year, and the average prevalence would be 54 per 100,000 [5]. Bak-Nielsen et al [6] have published an average incidence rate of 3.60 per 100,000 person-years in Denmark. The prevalence of diagnosed keratoconus in the Netherlands National Patient Register 1977–2015 was 44 per 100,000 persons [7]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.