Abstract

To meet the technical challenge of recovering human IgG fusion protein from transgenic whole goat milk at reasonable cost with high purity and yield, a predictive aggregate transport model for microfiltration has been developed (Baruah and Belfort, 2003). Here, to test the model's predictability of permeate flux and mass transport, a comprehensive series of experiments with varying wall shear rate, feed temperature, feed concentration, and module design are presented. A very good fit was obtained between the model predictions and measurements for a wide variety of experimental conditions. For microfiltration module design comparison, a linear hollow fiber module (representing current commercial technologies) gave lower permeation flux and higher yield than a helical hollow fiber module (representing the latest self-cleaning methodology). These results are easily explained with the model that is now being used to define operating conditions for maximizing performance. The procedure described by the model is generalizable and can be used to obtain optimal filtration performance for applications other than milk.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.