Abstract

This brief presents a practical application of the conventional multiloop control method for the temperature control of a television (TV) glass furnace. To control the temperatures of the TV glass furnace, two inputs and three outputs are selected as major process variables. With the process experimental data, a multi-input multi-output model is established as a combination of input-output transfer functions in the form of the first-order-plus-dead-time system. Based on the plant models, a multiloop control, which is a combination of cascade and single loops, is used, and stability and robustness are examined with respect to major uncertain model parameters. Practical implementation in a distributed control system showed satisfactory results of the proposed control algorithm for the 150-ton/day-production furnace.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.