Abstract

Passive harmonic filters (PHF) are commonly used in conventional potline rectifier transformers (Rectiformer) schemes of aluminum smelters to improve the power quality and reduce harmonic distortions to an acceptable level. However, changes in operating conditions and system configuration affect the performance capability of PHF in attenuating harmonics. In this paper, a Rectiformer scheme with hybrid-shunt active power filter (SAPF) is used instead of PHF and compared with the other commonly applied schemes in aluminum smelter in terms of harmonic attenuation capability. The SAPF potline Rectiformer scheme and other schemes are modeled and simulated using MATLAB/Simulink. A control strategy suitable for potline load behavior is furnished in this paper for SAPF. The simulation results reveal the performance superiority of the proposed SAPF as compared to the conventional and ALBA pot line (PL) 6 schemes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.