Abstract

The principles of a hybrid bio-impedance technique are implemented in a novel, lung resistivity monitoring system (“CardioInspect” Tel-Aviv University, Israel). The system is to be utilized in the clinic or at home, for daily monitoring of patients suffering from pulmonary edema. The developed system consists of an eight-electrode belt worn around the thorax, an electronic unit containing analog and digital boards, and a stand-alone DSP based system with a designated software to analyze the data. A Newton–Raphson algorithm based on the finite-volume method is employed for the optimization of the left and right lung resistivity values, making use of the voltage measurements retrieved from opposite current injections. In this preliminary study, 33 healthy volunteers were measured with the system during tidal respiration, yielding symmetric mean left and right lung resistivity values of (1205 ± 163, 1200 ± 165) (Ω cm). The system reproducibility was better than 2% for both within and between tests measurements, and no dependency between the reconstructed values and various anthropometric parameters was found.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.