Abstract

The current recommendations for establishing intra-laboratory reference limits (RLs) cannot be fulfilled by most laboratories because of the expense involved. In the current study, a bimodal method was developed to derive RLs from data stored in a laboratory information system without any assumption concerning the distribution of the diseased subgroup. A smoothed kernel density function (D(mix)) was estimated for the distribution of combined data for non-diseased and diseased adult subjects. It was assumed that the "central" part of the distribution represents the non-diseased population, which was defined and used to estimate a Gaussian distribution of either the original values or Box-Cox transformed data. This normal distribution was now considered the distribution of the non-diseased subgroup (D(nd)). Percentiles were calculated to obtain retrospective RLs. The density function of the diseased subgroup (D(d)) was calculated by subtracting the non-diseased density function from D(mix) (D(d)=D(mix)-D(nd)). The intersection point of the D(nd) and D(d) curves identified the RL with the highest diagnostic efficiency. The model was applied to catalytic activity concentrations of several enzymes with data from different laboratories. The RLs obtained were similar to recently published consensus values. Differences between laboratories were small but significant. Gender stratification was necessary for alanine aminotransferase (ALT), aspartate aminotransferase (AST), and gamma-glutymaltransferse (gamma-GT), not significant for lipase and amylase and inconsistent among the laboratories for alkaline phosphatase (AP) and lactate dehydrogenase (LDH). Age stratification was only tested for two groups (18-49 and >or=50 years) and was significant for AST (females only), gamma-GT and lipase, not significant for amylase and inconsistent for AP, LDH and ALT. For gamma-GT, further stratification for age in decades was necessary for males. Creatine kinase MB (CK-MB) values were not stratified owing to the low number of data available. Retrospective RLs derived from intra-laboratory data pools for the catalytic activity concentration of enzymes using a modified procedure plausibly agreed with published consensus values. However, most RLs varied significantly among laboratories, thus supporting the "old" plea for intra-laboratory RLs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.