Abstract

Purpose: We developed a plan quality classification model to assess IMRT plan quality of prostate cancer patients for automatic plan quality control. Methods : For hollow organs such as rectum and bladder, dose-wall-histogram (DWH) was used to evaluate OAR dose sparing in our institution. Correspondingly, we proposed a new descriptor called overlap-wall-histogram (OWH) to describe the complex spatial relationship between PTV and a hollow organ. Two metrics calculated from the OWH and DWH are introduced to quantitatively evaluate the difficulty of patient geometry for planning and plan quality in terms of OAR sparing, respectively. A linear correlation between these two metrics was observed after plotting plan quality metric as a function of geometry difficulty metric studied from a database of prostate cases treated in our institution with acceptable plan quality. Thus, a fitting line was built acting as the boundary of high quality and poor quality plans. A query plan falling above the boundary is assessed as high quality, vice versa poor quality. Results: 15 prostate IMRT plans were used to test our model. One was identified as poor quality and the others were common-level. After re-planning all plans, the dose constraints for bladder wall W75 (percentage of wall receiving more than 75Gy), W 70 , W 65 and W 60 can be reduced by 3.34%, 3%, 6.99%, 6.54% for that poor quality plan and 1.11%, 0.95%, 1.45% and 1.81% averagely for the common-level quality group, without sacrificing PTV coverage and rectum dose sparing. Conclusion : An effective model was built to provide automatic IMRT plan quality control by evaluating hollow OAR dose sparing for prostate cancer patients. Furthermore, for the query plan with poor quality, potential improvement of plan quality can be estimated and a good reference plan with similar or harder geometry can be automatically chosen from our database to help guide the re-planning if necessary. --------------------------- Cite this article as : Song T, Tian Z, Jia X, Zhou L, Jiang SB, Gu X. A plan quality classifier derived with overlap-wall-histogram of hollow organs for automatic IMRT plan quality control of prostate cancer cases. Int J Cancer Ther Oncol 2014; 2(2):020241. DOI: 10.14319/ijcto.0202.41

Highlights

  • 15 prostate IMRT plans were used to test our model

  • We developed a plan quality classification model to assess IMRT plan quality of prostate cancer patients for automatic plan quality control

  • A query plan falling above the boundary is assessed as high quality, vice versa poor quality

Read more

Summary

Introduction

15 prostate IMRT plans were used to test our model. One was identified as poor quality and the others were common-level. A plan quality classifier derived with overlap‐wall‐histogram of hollow organs for automatic IMRT plan quality control of prostate cancer cases Purpose: We developed a plan quality classification model to assess IMRT plan quality of prostate cancer patients for automatic plan quality control.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call