Abstract
This article summarizes the dosimetric results of an International Atomic Energy Agency coordinated research program to investigate the feasibility of adopting guidance levels for invasive coronary artery procedures. The main study collected clinical data from hospitals located in five countries. A total of 2265 coronary angiograms (CA) and 1844 percutaneous coronary interventions (PCI) were analyzed. Substudies evaluated the dosimetric performance of 14 fluoroscopes, skin dose maps obtained using film, the quality of CA procedures, and the complexity of PCI procedures. Kerma-area product (PKA) guidance levels of 50 and 125 Gy cm2 are suggested for CA and PCI procedures. These levels should be adjusted for the complexity of the procedures performed in a given institution.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.