Abstract

The development of cost-effective technologies for treating and disinfecting wastewater to a level that makes it economically valuable, environmentally sustainable, and health-safe for reuse is of utmost importance. In this study, a direct descending filtration pilot unit was designed, assembled, and tested within a municipal wastewater treatment plant to produce nonpotable reclaimed wastewater. Bench-scale tests were performed to define the optimum coagulant type and dosage (Poly aluminium chloride, 15 mg L−1). The pilot plant performed best at a filtration rate of 15 m h−1 in a bed of commercial building silica sand with an average particle size of 0.93 mm, resulting in a net production of 0.103 m3 h−1 of treated water. The removal efficiencies for apparent color, E. coli, turbidity and total suspended solids were 86.8 ± 2.3%, 86.8 ± 3.6%, 76.9 ± 6.9% and 68.7%, respectively. After a final stage of chlorine disinfection, the E. coli removal was higher than 99.7%. All the resulting parameters were within the recommended standards for nonpotable uses, such as landscape irrigation, dust and fire control, soil compaction, and street cleaning.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.