Abstract

According to the characteristic of high ammonia nitrogen concentration of Huaihe River in winter, a pilot-scale test was studied in this paper. This paper compared the start-up and operation performance of zeolite biofilter, quartz sand + activated carbon biofilter and zeolite + activated carbon composite biofilter in lower temperature. The results show that three kinds of biofilters for NH4+-N have high remove effects. Average removal rate of zeolite biofilter, quartz sand + activated carbon biofilter, zeolite + activated carbon composite biofilter for NH4+-N were 73%,64% and 78% and effluent NH4+-N concentration were 0.31mg/L,0.24mg/L,0.21mg/L. Average CODMn removal rate of three kinds of biofilters were 5%,13% and 28%. Zeolite + activated carbon composite biofilter does not exist to NO2-N accumulation phenomenon and showed good ability to start-up and running.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.