Abstract
BackgroundThe THUNDERBEAT is a multi-functional energy device which delivers both ultrasonic and bipolar energy, but there are no randomized trials which can provide more rigorous evaluation of the clinical performance of THUNDERBEAT compared to other energy-based devices in colorectal surgery. The aim of this study was to compare the clinical performance of THUNDERBEAT energy device to Maryland LigaSure in patients undergoing left laparoscopic colectomy.MethodsProspective randomized trial with two groups: Group 1 THUNDERBEAT and Group 2 LigaSure in a single university hospital. 60 Subjects, male and female, of age 18 years and above undergoing left colectomy for cancer or diverticulitis were included. The primary outcome was dissection time to specimen removal (DTSR) measured in minutes from the start of colon mobilization to specimen removal from the abdominal cavity. Versatility (composite of five variables) was measured by a score system from 1 to 5 (1 being worst and 5 the best), and adjusted/weighted by coefficient of importance with distribution of the importance as follow: hemostasis 0.275, sealing 0.275, cutting 0.2, dissection 0.15, and tissue manipulation 0.1. Other variables were: dryness of surgical field, intraoperative and postoperative complications, and mortality. Follow-up time was 30 days.Results60 Patients completed surgery, 31 in Group 1 and 29 in Group 2. There was no difference in the DTSR between the groups, 91 min vs. 77 min (p = 0.214). THUNDERBEAT showed significantly higher score in dissecting and tissue manipulation in segment 3 (omental dissection), and in overall versatility score (p = 0.007) as well as versatility score in Segment 2 (retroperitoneal dissection p = 0.040) and Segment 3 (p = 0.040). No other differences were noted between the groups.ConclusionsBoth energy devices can be employed effectively and safely in dividing soft tissue and sealing mesenteric blood vessels during laparoscopic left colon surgery, with THUNDERBEAT demonstrating some advantages over LigaSure during omental dissection and tissue manipulation.ClinicalTrial.gov # NCT02628093.
Highlights
The THUNDERBEAT is a multi-functional energy device which delivers both ultrasonic and bipolar energy, but there are no randomized trials which can provide more rigorous evaluation of the clinical performance of THUNDERBEAT compared to other energy-based devices in colorectal surgery
No other differences were noted between the groups. Both energy devices can be employed effectively and safely in dividing soft tissue and sealing mesenteric blood vessels during laparoscopic left colon surgery, with THUNDERBEAT demonstrating some advantages over LigaSure during omental dissection and tissue manipulation
LigaSure demonstrated a higher score for “less pain and less fatigue” from use the of instrument handle but it was not statistically significant (p = 0.08) (Table 7). The goal of this randomized trial was to evaluate the clinical performance between TB and Maryland LigaSure Energy Devices with primary outcome dissection time to specimen removal (DTSR)
Summary
The THUNDERBEAT is a multi-functional energy device which delivers both ultrasonic and bipolar energy, but there are no randomized trials which can provide more rigorous evaluation of the clinical performance of THUNDERBEAT compared to other energy-based devices in colorectal surgery. The aim of this study was to compare the clinical performance of THUNDERBEAT energy device to Maryland LigaSure in patients undergoing left laparoscopic colectomy. The primary outcome was dissection time to specimen removal (DTSR) measured in minutes from the start of colon mobilization to specimen removal from the abdominal cavity. Versatility (composite of five variables) was measured by a score system from 1 to 5 (1 being worst and 5 the best), and adjusted/weighted by coefficient of importance with distribution of the importance as follow: hemostasis 0.275, sealing 0.275, cutting 0.2, dissection 0.15, and tissue manipulation 0.1. Conclusions Both energy devices can be employed effectively and safely in dividing soft tissue and sealing mesenteric blood vessels during laparoscopic left colon surgery, with THUNDERBEAT demonstrating some advantages over LigaSure during omental dissection and tissue manipulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.